Flush Floor
Aeration Systems Custom Designed From Westeel
Custom Flush Floor Aeration systems are available for farm, commercial,
and export sales. They include a wide variety of floor layouts and
floor materials for an extensive range of bin sizes. Flush floor
systems provide the optimum aeration performance. Flush floor Aeration
Systems are shipped complete and pre-cut ready to install in formed
concrete ducts. Fans and transitions must be purchased separately.
Flush Floor Aeration systems include where necessary:
|
Cor-Perf Flush Floor Aeration System
- Corrugated perforated sheets
- Solid sheets
- Monorail and legs
- Teebars
- Flashing
- Tiebars
|
Cor-Lok Flush Floor Aeration System
or Channel-Lok Flush Floor Aeration System
- Cor-lok or Chan-lok planks
- Solid cover material
- Grandstands
- Teebars
- Flashing
|
Aeration systems do not include fans or transitions. These must
be ordered separately.
The two most important factors in choosing a system are eave height
(this directly effects airflows) for a particular diameter and desired
airflow rate per bushel.
The eave height must not be exceeded for a system to be effective.
Use of a floor for an eave height more than stated may lead to inadequate
perforated floor area, therefore less airflow. The number of floor
supports and floor gauge may also be less than recommended.
The airflow rate, cfm/bu, must not be exceeded for a system to
be effective. Use of airflows higher than listed for a particular
floor may lead to increased static pressures and poor fan performance.
Aeration floors are sized on a bin volume basis, therefore the
grain to be used has no effect on floor characteristics (except
for customer preference, very small grains, or use of the bin for
materials other than grain). The final airflow rate is determined
by the fans necessary to meet the grain conditions.
The floor layout is determined by customer needs, i.e. number of
fans, fan location, unloading restrictions, etc., along with good
design principles.
"I" configuration is used in bins from 15 to 21' in diameter.
"Y" configuration is used in bins 24 to 36' in diameter,
and "Double T" configuration is used in bins 33 to 48'
in diameter.
These systems are designed for aeration only, not drying. These
systems are intended for use in bins no taller than 7 rings (18'8"
eave) 2.66 corrugation or 5 rings (18'4" eave) 4.00 "
corrugation. Maximum recommended airflow rate is 1/10 cfm/bu.
Should it be necessary to use this type of floor in taller bins,
up to 33' eave height, refer to Skyway for specifications. Unlike
the "duct assembly" system set into the concrete, these
floors require "formed" tunnels for use with cor-lok planks.
These systems take advantage of the maximum span for cor-lok at
33' eave height and need no grandstands. Please contact Skyway for
proper concrete dimensions.
|