Tower Grain Dryer Specifications
|
U1012 |
U1212 |
U1512 |
U1812 |
U2012 |
U2412 |
U2518 |
U3018 |
U3518 |
U4018 |
U4718 |
U5024 |
U6024 |
U7024 |
Bu/Hr. 20% - 15%* |
1000 |
1200 |
1500 |
1800 |
2000 |
2400 |
2500 |
3000 |
3500 |
4000 |
4700 |
5000 |
6000 |
7000 |
Bu/Hr. 25%-15%* |
600 |
720 |
900 |
1080 |
1200 |
1440 |
1500 |
1800 |
2100 |
2400 |
2820 |
3000 |
3600 |
4200 |
Heat Holding Bu. |
615 |
737 |
915 |
1113 |
1275 |
1521 |
1472 |
1925 |
2208 |
2642 |
2941 |
3469 |
4026 |
4436 |
Cool Holding Bu. |
215 |
288 |
305 |
400 |
434 |
481 |
642 |
642 |
812 |
831 |
1136 |
1238 |
1295 |
1499 |
Total Holding Bu. |
1299 |
1494 |
1689 |
1982 |
2178 |
2471 |
3090 |
3543 |
3996 |
4449 |
5053 |
6336 |
6950 |
7564 |
Drying Airflow (CFM) |
48,000 |
62,300 |
77,800 |
85,600 |
94,600 |
110,300 |
128,550 |
148,200 |
174,300 |
206,400 |
226,200 |
275,100 |
296,100 |
343,500 |
Burner Cap. (BTUx1000) |
11,000 |
13,457 |
16,805 |
18,490 |
20,434 |
23,825 |
27,767 |
32,011 |
37,649 |
44,582 |
48,859 |
59,422 |
63,958 |
74,196 |
Ave. Heat (BTUx1000) |
6500 |
7738 |
9663 |
10,632 |
11,749 |
13,699 |
15,966 |
18,406 |
21,648 |
25,635 |
28,094 |
34,167 |
36,776 |
42,663 |
Blower HP |
50 hp Axial |
60 |
75 |
75 |
100 |
100 |
(3) 40 |
(3) 50 |
(3) 60 |
(3) 75 |
(3) 75 |
(3)100 |
(3) 100 |
(3)125 |
AC Drive Metering HP |
1 |
1 ½ |
1 ½ |
1 ½ |
1 ½ |
1 ½ |
2 |
2 |
2 |
2 |
2 |
3 |
3 |
3 |
Grain Column |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
12.75” |
Tower Diameter |
12’0” |
12’0” |
12’0” |
12’0” |
12’0” |
12’0” |
18’0” |
18’0” |
18’0” |
18’0” |
18’0” |
24’0” |
24’0” |
24’0” |
Overall Height |
48’ |
54 |
61’ |
71’ |
2000 |
2400 |
68’ |
78’ |
88’ |
98’ |
111’ |
100’ |
110’ |
120’ |
Sukup Manufacturing Co provides this information to assist you in choosing the optimal equipment for your situation. Many factors, such as grain variety, maturity levels, grain cleanliness, weather conditions and operation/management, can affect the performance of your tower dryer and results may vary. This information is calculated and is not a guarantee of product specifications or performance. Based on these factors, Sukup specifications should only be used as estimates, and not as a warranty, express or implied, of how a particular Sukup unit will perform under your operating conditions. Because we are continually improving Sukup products, changes may occur that may not be reflected in the specifications.
*BU/Hr (bushels per hour) listed are wet bushels, No. 2 shelled yellow corn at listed moisture content and are estimates based on drying principles, field results and computer simulation.
|